Preview

Russian journal of hematology and transfusiology

Advanced search

Experience of implementing a system of qualification plasma for fractionation donors

https://doi.org/10.18821/0234-5730-2016-61-2-87-91

Abstract

The rate of the detection of the markers of the Hepatitis B virus (HBV), Hepatitis C virus (HCV) and Human Immunodeficiency Virus 1 and 2 types (HIV-1/HIV-2) among donors of plasma for fractionation over the period of 2012--2013 was evaluated. The incidence rate of markers of hemotransmissible infections (HTI) among donors of plasma for fractionation amounted for HIV-1/HIV-2: 0.03–0.07%, for HBV: 0.15–0.21% and for HCV: 0.35–0.37%. These indices are 1.5–2 times lower than the all-Russian indices, obtained from the results of activity of the blood service in 2012 and2013. Inthe group of "approved donors" markers of HIV-1/HIV-2, HBV and HCV were detected significantly less often (more than 10, 20 and 23 times, respectively) than among potential plasma donors. There was performed an epidemiological evaluation of the population of donors of plasma for fractionation in conformity with the standards of Plasma Protein Therapeutics Association (PPTA). The data obtained testify to the efficiency of the introduced system of qualification of donors of plasma for fractionation. The introduced system provided a level of infectious safety of stored plasma complying with international industry standards of quality – PPTA.

About the Authors

I. V. Paramonov
Kirov Scientifc-Research Institute of Hematology and Blood Transfusion; Russian Medical Research and Production Center "Rosplazma"
Russian Federation

Kirov, 610027;

Kirov, 610002



A. L. Poptsov
Russian Medical Research and Production Center "Rosplazma"
Russian Federation

Poptsov Aleksandr L., head of the laboratory quality control

Kirov, 610002



A. V. Rylov
Kirov Scientifc-Research Institute of Hematology and Blood Transfusion
Russian Federation

Kirov, 610027



References

1. WHO. Recommendation for the production, control and regulation of human plasma for fractionation. 2005. Available at: http://www.who.int/bloodproducts/05-2019%20Human%20plasma%20fraction.pdf.

2. On approval of the medical examination of the blood and its components donor: order Ministry of Health of Russia № 364 on 14.09.2001. (in Russian) Available at: http://www.consultant.ru

3. PPTA. International Quality Program Plasma Qualifed Donor Standard. v.4.0. 2014. Available at: http://www.pptaglobal.org/images/IQPP/QualifedDonorStdFinal1.pdf.

4. PPTA. International Quality Program Plasma Viral Marker Standard ver.4.1. 2009. Available at: http://www.pptaglobal.org/images/IQPP_ViralMarker_V4_1.pdf.

5. On approval of rules and methods research and selection rules of donor blood required for the application and implementation of technical regulations on the requirements for the safety of blood and its products, blood-substituting solutions and equipment used in transfusion, infusion therapy: resolution of the Russian Government №1230 on 31.12.10. (in Russian). Available at: http://www.consultant.ru

6. Chechetkin A.V., Grigoriyan M.Sh., Makeev A.B., Vorobey L.G., Danilchenko V.V. Blood Service of the Russian Federation in 2012. Transfuziology. Russian journal (Transfuziologiya). 2013; 3: 4–14. (in Russian)

7. Chechetkin A.V., Grigoriyan M.Sh., Makeev A.B., Vorobey L.G., Danilchenko V.V. Activities of institutions blood service of the Russian Federation in 2013. Transfuziology. Russian journal (Transfuziologiya). 2014; 3: 4–13. (in Russian)

8. EMA. Guideline on epidemiological data on blood transmissible infections. EMA/CHMP/BWP/548524/2008. 2010. Available at: http://www.ema.europa.eu/docs/en_GB/document_library/Scientifc_guideline/2010/10/WC500097728.pdf.

9. Agreement on common principles and rules of circulation of drugs in the framework of the Eurasian Economic Union: the agreement EEU on 23.12.14. (in Russian). Available at: http://www.consultant.ru

10. Belousova E.A., ed. On the state sanitary and epidemiological welfare in the Kirov region in 2012: state report. 2013. (in Russian). Available at: http://www.43.rospotrebnadzor.ru/documents/gosregdoklad/publications/svoddokl2012.pdf

11. On the state sanitary and epidemiological welfare in the Kirov region in 2013: state report. 2014. (in Russian). Available at: http://www.43.rospotrebnadzor.ru/documents/gosregdoklad/publications/svoddokl2013.pdf


Review

For citations:


Paramonov I.V., Poptsov A.L., Rylov A.V. Experience of implementing a system of qualification plasma for fractionation donors. Russian journal of hematology and transfusiology. 2016;61(2):87-91. (In Russ.) https://doi.org/10.18821/0234-5730-2016-61-2-87-91

Views: 481


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0234-5730 (Print)
ISSN 2411-3042 (Online)